$104.95
859902WPS surge protector kit with a 2 ft LMR-400 N male-to-N male jumper and 30 ft of 10 AWG grounding wire. N female protector ports, DC–3 GHz, 50 ohms, DC pass-through. Confirm site grounding and equipment compatibility.
This WPS kit combines an inline coaxial surge protector, a short coax jumper, and grounding wire for an external-antenna installation. Select it for the specified connectors and frequency range.
Contact WPS to confirm any additional grounding attachments and the hardware required for your installation.
| Frequency range | DC–3 GHz |
|---|---|
| Impedance | 50 ohms |
| VSWR | 1.3:1 maximum |
| Insertion loss | 0.4 dB maximum |
| Gas discharge tube | 230 V, replaceable |
| DC behavior | Passes DC |
| Protection direction | Bidirectional |
Install inline between the outdoor antenna cable and the equipment cable, and bond the protector to the site grounding system according to the product instructions and applicable installation requirements. The included jumper provides an N male connection at each end; confirm that your equipment and other cables match.
Surge protection reduces exposure to transient surges but does not guarantee protection from a lightning strike.